BATTERY INFO
Capacity
2,560 Wh
Type
LiFePO₄
Life Cycles
6,000+ cycles to 70% original capacity
Shelf-life
Recharge to 40%-60% every 3-6 months
Management System
MPPT controller, BMS, etc.
OUTPUT
Inverter Type
Pure sine wave
AC Outlets
3,600W Max. in total, 230V, 15A Max. each port, 50/60Hz
DC Outlets
2* USBA-15W 2* USBC--100W*1&140W*1 1* 12V/10A Cigarette Lighter Port 1* 12V/30A Anderson Port
Lifting Power
5,400W
INPUT
AC Input
230V, 50/60Hz, 15A Max. 3,200W Max. with bypass
Solar Input
3,000 W Max. XT60: 1,000 W 12V~60V, 25 A Max. MC4: 2,000 W 60V~450V, 16 A
Car Input
12V or 24V via cigarette lighter port
Maximum Input
3,200 W Max. (4,600 W Max. with expansion unit)
GENERAL
Weight
26.9 kg/59.3 lbs
Dimensions (L × W × H)
525 × 327 × 211 mm / 20.67 × 12.87 × 8.31 in
Charging Temperature
32°F to 104°F / 0°C to 40°C
Discharging Temperature
-4°F to 104°F / -20°C to 40°C
Storage Temperature
-4℉ to 104℉ / -20℃ to 40℃
UPS Switching Time
≤ 15 ms
App Control
Yes, via WiFi & Bluetooth
Pass-through Charging
Yes
Warranty
5 Years
Noise
50 dB Max
Scalability
Up to 6 × B300K / B500K per unit
Certifications
FCC, UL Standard, TELEC, CE, NTC, RCM, LOA, ICASA
Disclaimers
* Apex 200 provides 3,200W of continuous AC output as a standalone unit. Up to 3,600W of AC output is available when a compatible expansion battery is connected.
* UPS mode is disabled by default and must be enabled in the BLUETTI app. Automatic transfer applies only to compatible devices connected to supported Apex 200 AC outlets.
* Apex 200 offers three AC charging modes: Silent, Standard, and Turbo. The charging times shown on this page are based on Turbo charging under BLUETTI internal test conditions. Actual charging time may vary depending on input power, system configuration, temperature, and connected loads.
* Apex 200 supports up to 3,000W of combined solar input: up to 2,000W through the high-voltage MC4 input and up to 1,000W through the low-voltage XT60 input. Depending on the regional version, the high-voltage MPPT input range is 60–450V. Maximum solar input requires a compatible dual-input solar setup. Actual input and charging speed vary with panel configuration, sunlight, temperature, shading, and other operating conditions. Rooftop solar arrays must remain within the applicable voltage, current, and power limits; additional equipment and professional installation may be required.
* Runtime data is based on BLUETTI internal testing under specified conditions. Actual runtime may vary depending on connected loads, usage patterns, battery state of charge, temperature, and other operating conditions.
* Smart AC outlet controls require setup in the BLUETTI app. Supported AC outlets can be controlled individually, scheduled, and configured to turn off selected non-essential loads when the battery reaches a user-defined state of charge. Remote functions require Apex 200 to be online. These controls are designed to help manage energy use and do not guarantee a specific runtime.
* The Severe Weather Alert feature notifies users when qualifying severe weather is forecast and prompts them to choose whether to enable automatic charging. Charging does not begin without the required user setting or authorization. Alerts require network connectivity, location and notification permissions, and availability in the applicable region. Alert timing and coverage depend on the weather data provider.
* Capacity Expansion: One Apex 200 supports up to six compatible B300K or B500K expansion batteries. With B500K batteries, nominal system capacity ranges from 7.68 kWh with one battery to 33.28 kWh with six batteries. A single expanded system supports up to 3,600W of AC output.
* Multi-Unit Expansion: With Hub A1 and the required system accessories, two or three Apex 200 systems can be linked. The maximum configuration—three Apex 200 units with eighteen B500K batteries—provides up to 6,000W of combined AC output and 99.84 kWh of nominal capacity. Expansion batteries, Hub A1, cables, and other required accessories may be sold separately. Actual usable energy and runtime vary depending on system configuration, connected loads, settings, and operating conditions.
* Product images are for illustrative purposes. Specifications, included accessories, and feature availability may vary by model, regional version, and production batch. Refer to the product details and documentation for the version purchased.
Product Notes
AC Output: Standalone continuous output is 3,200W. Up to 3,600W continuous output requires compatible expansion batteries or supported AC/solar input conditions.
Energy Density: Compared with selected 3 kWh-class power stations, 20% refers to gravimetric energy density (Wh/kg) and 50% to volumetric energy density (Wh/L), not direct weight or volume reductions.
Solar Charging: Up to 3,000W combined input (2,000W high-voltage + 1,000W low-voltage) requires compatible solar configurations. Actual charging performance varies with sunlight, panel setup, and operating conditions.
Battery Expansion: Each Apex 200 supports up to six compatible expansion batteries. Maximum capacity of 99.84kWh and combined output of 6,000W require three Apex 200 units, eighteen B500K batteries, Hub A1, and compatible accessories, sold separately.
Fast Charging: Maximum AC charging power requires a compatible high-power AC connection and specified charging cable. Actual input depends on outlet, circuit, and configuration. Charging times are based on BLUETTI internal testing and may vary. Some charging methods require additional accessories.
UPS Backup: UPS mode must be enabled in the BLUETTI app. Automatic switching applies to properly connected devices. Transfer performance varies by operating conditions and may not meet every device's requirements.
Smart AC Control: Outlet control, scheduling, and battery-level automation require compatible settings in the BLUETTI app. Feature availability may vary by firmware and connectivity.
Battery Life & Safety: Cycle-life figures are based on BLUETTI laboratory testing to 70% of original battery capacity. Actual results vary. UL 94 5VA applies only to specified materials or components, not the complete system.