| Type designation |
SH6.0RS |
| Input (DC) |
|
| Recommended max. PV input power |
13000 Wp |
| Max. PV input voltage |
600 V |
| Min. operating PV voltage / Start-up input voltage |
40 V / 50 V |
| Rated PV input voltage |
360 V |
| MPP voltage range |
40V – 560 V |
| No. of independent MPP inputs |
2 |
| No. of PV strings per MPPT |
1 / 1 |
| Max. PV input current |
32 A (16 A / 16 A) |
| Max. DC short-circuit current |
40 A (20 A / 20 A) |
| Max. current for input connector |
20 A |
| Battery Data |
|
| Battery type |
Li-ion battery |
| Battery voltage |
80 V - 460 V |
| Max charge / discharge current |
30 A / 30 A |
| Max charge / discharge power |
6600 W |
| Input / Output ( AC ) |
|
| Max. AC power from grid |
13000 VA |
| Rated AC output power |
6000 W |
| Max. AC output apparent power |
6000 VA |
| Rated AC output apparent power |
6000 VA |
| Rated AC output current (at 230V) |
26.1 A |
| Max. AC output current |
27.3 A |
| Rated AC voltage |
230 V |
| AC voltage range |
154 V – 276 V |
| Rated grid frequency |
50 Hz / 60 Hz |
| Grid frequency range |
45 Hz – 55 Hz / 55 Hz – 65 Hz |
| Harmonic (THD) |
< 3% (of rated power) |
| Power factor at rated power / Adjustable power factor |
> 0.99 at default value at rated power |
| Feed-in phases / connection phases |
1 / 1 |
| Backup Data (on-grid mode) |
|
| Rated output power for backup load |
6000 W |
| Rated output current for backup load |
27.3 A |
| Backup Data (off-grid mode) |
|
| Rated voltage |
230V (±2%) |
| Rated grid frequency |
50 Hz / 60 Hz (±0.2%) |
| Output voltage harmonic (THD) |
< 2% |
| Switch time to emergency mode |
< 10 ms |
| Rated output power |
6000 W / 6000 VA |
| Peak output power |
8400 VA, 10 s |
| Efficiency |
|
| Max. efficiency |
97.7% |
| European efficiency |
97.3% |
| Protection & Function |
|
| Grid monitoring |
Yes |
| DC reverse polarity protection |
Yes |
| AC short circuit protection |
Yes |
| Leakage current protection |
Yes |
| DC switch (solar) |
Yes |
| DC Overcurrent Protection (Battery) |
Yes |
| Surge Protection |
DC Type II / AC Type II |
| PID recovery function |
Yes |
| Parallel operation on grid port / Max. No of inverters |
Master-slave mode / 3 |
| Battery input reverse polarity protection |
Yes |
| General Data |
|
| Topology (Solar / Battery) |
Transformerless / Transformerless |
| Degree of protection |
IP65 |
| Dimensions (W * H * D) |
490 mm * 340 mm * 170 mm |
| Weight |
18.5 kg |
| Mounting method |
Wall-mounting bracket |
| Operating ambient temperature range |
-25 ℃ – 60 ℃ |
| Allowable relative humidity range (Non-condensing) |
0% – 100% |
| Cooling method |
Natural convection |
| Max. operating altitude |
4000 m |
| Display |
LED digital display & LED indicator |
| Communication |
RS485 / Ethernet / WLAN / CAN |
| DI / DO |
DI * 4 / DO * 1 / DRM |
| DC connection type |
MC4 (PV) / Evo2 Compatible (Battery) |
| AC connection type |
Plug and Play *** |
| Grid compliance |
IEC 62109-1/2, IEC 62477-1, AS/NZS 4777.2:2020 |
| Country of manufacture |
China |