Type designation |
SG110CX |
Input (DC) |
|
Max. PV input voltage |
1100 V ** |
Min. PV input voltage / Start-up input voltage |
200 V / 250 V |
Nominal PV input voltage |
585 V |
MPP voltage range |
200 – 1000 V |
No. of independent MPP inputs |
9 |
No. of PV strings per MPPT |
2 |
Max. PV input current |
26 A * 9 |
Max. DC short-circuit current |
40 A * 9 |
Output (AC) |
|
AC output power |
110 kVA @ 45 ℃ / 100 kVA @ 50 ℃ |
Max. AC output current |
158.8 A |
Nominal AC voltage |
3 / N / PE, 400 V |
AC voltage range |
320 – 460 V |
Nominal grid frequency / Grid frequency range |
50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz |
Harmonic (THD) |
< 3 % (at nominal power) |
Power factor at nominal power / Adjustable power factor |
> 0.99 / 0.8 leading – 0.8 lagging |
Feed-in phases / AC connection |
3 / 3-PE |
Efficiency |
|
Max. efficiency |
98.7 % |
European efficiency |
98.5 % |
Protection and Function |
|
DC reverse polarity protection |
Yes |
AC short-circuit protection |
Yes |
Leakage current protection |
Yes |
Grid monitoring |
Yes |
Ground fault monitoring |
Yes |
DC switch |
Yes |
AC switch |
No |
PV string monitoring |
Yes |
Q at night function |
Yes |
PID recovery function |
Yes |
Arc fault circuit interrupter (AFCI) |
Optional |
Surge protection |
DC Type II (optional: Type I + II) / AC Type II |
General Data |
|
Dimensions (WHD) |
1051 * 660 * 362.5 mm |
Weight |
89 kg |
Topology |
Transformerless |
Degree of protection |
IP66 |
Night power consumption |
< 2 W |
Operating ambient temperature range |
-30 to 60 ℃ (> 50 ℃ derating) |
Allowable relative humidity range |
0 – 100 % |
Cooling method |
Smart forced air cooling |
Max. operating altitude |
4000 m (> 3000 m derating) |
Display |
LED, Bluetooth+APP |
Communication |
RS485 / Optional: WLAN, Ethernet |
DC connection type |
MC4 (Max. 6 mm²) |
AC connection type |
OT / DT terminal (Max. 240 mm²) |
Compliance |
IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N. 4110:2018, VDE-AR-N 4120:2018, IEC 61000-6-3, EN 50549, AS/NZS. 4777.2:2015, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA |
Grid Support |
Q at night function, LVRT, HVRT, active & reactive power control and power ramp rate control |