Fronius Gen24 Primo 6kW 1 Phase 2 MPPT


Price:
Sale price$2,550.00

Description

Fronius Primo GEN24

Inverters for private photovoltaic systems with integrated basic backup power function

Our single-phase Fronius GEN24 inverter is the heart of private photovoltaic systems.
The Fronius GEN24 is equipped with PV Point, an integrated basic backup power function that supplies backup power to connected devices via a protected socket (as long as the sun is shining).
 
The Fronius Primo GEN24 boasts a wide range of features that support a sustainable, independent energy supply. Discover the key features for installers and their customers:
 
/ Intelligent energy management
/ Active cooling technology for a longer service life
/ Flexible and fast installation
/ Easy integration and management of Fronius or third-party components thanks to open interfaces 


Multi-award-winning


INPUT DATA

Number of MPP trackers 2
Max. input current (Idc max)
22 / 12 A
Max. short circuit current, module array*
36 / 19 A
DC input voltage range (Udc min - Udc max)
65 - 600 V
Feed-in start voltage (Udc start)
80 V
Nominal input voltage (Udc,r)
400 V
MPP voltage range (Umpp min - Umpp max)
230 - 480 V
Usable MPP voltage range 65 - 480 V
Number of DC connections 2+2
Max. PV generator power (Pdc max
9 kWpeak

OUTPUT DATA

AC nominal output (Pac,r)
6000 W
Max. output power (Pac max)
6000 VA
Max. grid power demand 6000 VA
Max. AC output current 27,5 A
Grid connection (Uac,r)
1~ NPE 220/230 V
AC voltage range (Umin - Umax)
155 - 270 V
Frequency (fr)
50 / 60 Hz
Frequency range (fmin - fmax)
45 - 65 Hz
Total harmonic distortion <3% @Pnom (230/400VAC 50Hz)
Power factor (cos φac,r)
0,8 - 1 ind,/cap,
Back-up power 1~NPE 220 V / 230 V
Nom. output current (220VAC)
27,3 A
Nom. output current (230VAC)
26,1 A

GENERAL DATA

Width
474 mm
Height
530 mm
Depth
165 mm
Weight 15,38 kg
Weight incl. packaging 19 kg
Degree of protection IP66
Protection class 1
Overvoltage category (DC / AC) 1)
2 / 3
Night-time consumption < 10 W
Inverter design Transformerless
Cooling Active Cooling
Installation Indoor and outdoor installation
Ambient temperature range -40°C - +60°C
Permitted humidity 0 - 100 %
Max. altitude 2)
4000
AC connection technology 3 pole AC push-in spring terminals 2.5 - 10 mm²
3 pole backup power push-in spring terminals 1.5mm² - 10mm²
2x PE-screw terminals 2.5 - 16 mm² and  3x 2,5 - 10mm²
Certificates and compliance with standards IEC 62109, IEC 62909, AS/NZS 4777.2, CEI 0-21, ABNT BNR 16149 und 16150, IEC 62116, IEC 61727, G98/G994)
Back-up power functions PV Point
Sound emissions 42 dB(A)
Interference emission class B

EFFICIENCY

Max. efficiency (PV - grid) 97,6 %
European efficiency (ηEU) 96,1 / 97,1 / 96,7 (230Vdc / 400Vdc / 480Vdc)
η at 5% Pac,r 3)
88,4 / 92,1 / 90,2 (230Vdc / 400Vdc / 480Vdc)
η at 10% Pac,r 3)
93,3 / 95,5 / 94,6 (230Vdc / 400Vdc / 480Vdc)
η at 20% Pac,r 3)
95,8 / 97,0 / 96,5 (230Vdc / 400Vdc / 480Vdc)
η at 25% Pac,r 3)
96,2 / 97,2 / 96,8 (230Vdc / 400Vdc / 480Vdc)
η at 30% Pac,r 3)
96,5 / 97,4 / 97,0 (230Vdc / 400Vdc / 480Vdc)
η at 50% Pac,r 3)
96,8 / 97,5 / 97,3 (230Vdc / 400Vdc / 480Vdc)
η at 75% Pac,r 3)
96,8 / 97,5 / 97,3 (230Vdc / 400Vdc / 480Vdc)
η at 100% Pac,r 3)
96,7 / 97,4 / 97,1 (230Vdc / 400Vdc / 480Vdc)
MPP adaptation efficiency 99,9

PROTECTION DEVICES

DC insulation measurement Yes
Overload behaviour Operating point shift, Power limitation
DC disconnector Yes
DC Reverse polarity protection Yes

INTERFACES

WLAN / 2x Ethernet LAN Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6x digital in/out + 6x digital in Interface to ripple control receiver, energy management
Emergency stop (WSD) Yes
Datalogger and web server Included
2x RS485 Modbus RTU SunSpec (third-party supplier) / Fronius Smart Meter, battery, Fronius Ohmpilot

OUTPUT DATA PV POINT

Max continuous output power 3000 VA
Nom. output current (Iac max)
13 A
Grid connection 1~NPE 220 V / 230 V
Frequency 50 Hz / 60 Hz
Max. switchover time PV-Point 23 s
Frequency in backup power mode 53 Hz

You may also like